A compact true-rms meter for HVAC (heating ventilation air conditioning) troubleshooting, the Fluke 116 was specifically designed for the HVAC professional. It has everything needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors.
Fluke 116 HVAC Multimeter Manual
Click the link(s) above to open the document(s) for this item. Should you wish to download it, right click on the link and select "Save Target As..." or "Save Link As...".
If you do not have Acrobat Reader, click here to download the latest version.
Features:
- Built-in thermometer for HVAC applications
- Microamps to test flame sensors
- Low input impedance: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak)
- CAT III 600 V safety rated
- Includes:
- HVAC Multimeter
- TL75 Test leads
- 80BK Integrated Temperature probe
- Holster
- Installed 9 V battery
Spec Summary:
Specifications |
|
Maximum voltage between
any terminal and earth ground: |
600 V |
Surge protection: |
6 kV peak per IEC 61010-1 600 VCAT III,
Pollution Degree 2 |
Display: |
Digital: 6,000 counts, updates 4 per second |
Bar graph: |
33 segments, updates 32 per second |
Operating Temperature: |
14 to 122°F (-10 to + 50°C) |
Storage Temperature: |
-40 to 140°F (-40 to + 60°C) |
Battery type: |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
Battery Life: |
400 hours typical, without backlight |
Accuracy Specifications |
|
DC millivolts: |
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 2.0% + 3 |
DC volts: |
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V |
Auto volts: |
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) |
AC millivolts1 true-rms: |
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
AC volts1 true-rms: |
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
Continuity: |
Range: 600 ohms
Resolution: 1 ohms
Accuracy: Beeper on < 20 ohms, off > 250 ohms;
detects opens or shorts of 500 µs or longer. |
Ohms: |
Range/Resolution: 600.0 ohms / 0.1 ohms
Range/Resolution: 6.000 kohms / 0.001 kohms
Range/Resolution: 60.00 kohms / 0.01 kohms
Range/Resolution: 600.0 kohms / 0.1 kohms
Range/Resolution: 6.000 Mohms / 0.001 Mohms
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 Mohms / 0.01 Moms
Accuracy: 1.5 % + 2 |
Diode Test: |
Range/Resolution: 2.000 V / 0.001 V
Accuracy: 0.9% + 2 |
Capacitance: |
Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 µF / 0.01 µF
Range/Resolution: 100.0 µF / 0.1 µF
Range/Resolution: 9999 µF / 1 µF
Range/Resolution: 100 µF to 1000 µF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 ¥ìF
Accuracy: 5% + 20% |
LoZ capacitance: |
Range: 1 nF to 500 µF
Accuracy: 10% + 2 typical |
Temperature2 (Type-K thermocouple): |
Range/Resolution: -40 to 400 °C / 0.1 °C
Accuracy: 1% + 102
Range/Resolution: -40°F to 752 °C / 0.2 °F
Accuracy: 1% + 182 |
AC µamps true-rms (45 Hz to 500 Hz): |
Range/Resolution: 600.0 µA / 0.1 µA
Accuracy: 1.0% + 2 |
DC µamps: |
Range/Resolution: 600.0 µA / 0.1 µA
Accuracy: 1.0% + 2 |
Hz (V or A input)2: |
Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.99 Hz / 0.1 Hz
Range/Resolution: 9.999 Hz / 0.001 Hz
Range/Resolution: 50.00 Hz / 0.01 Hz
Accuracy: 0.1% + 2 |
Notes:
1) All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.
Mechanical & General Specifications |
|
Size: |
Height: 10.875" (27.62 cm)
Length: 6.25" (15.875 cm)
Width: 2.203"(5.6 cm) |
Weight: |
1.34 lbs (607 g) |
Warranty: |
3 years |
|