The Fieldpiece Electronic Handle converts any Fieldpiece accessory head into a stand alone instrument
The Fieldpiece Electronic Handle has ranges to display the parameter without forcing you to move decimal points in your head while still providing 0.1mV resolution.
Fieldpiece Electronic Handle EHDL1 Manual
Click the link(s) above to open the document(s) for this item. Should you wish to download it, right click on the link and select "Save Target As..." or "Save Link As...".
If you do not have Acrobat Reader, click here to download the latest version.
Features:
- Works with all Fieldpiece accessory heads
- 200mV and 2000mV, AC and DC ranges for maximum readings to 1999 and resolution as good as 0.1
- MIN/MAX to record highest and lowest readings
- Data Hold button
- Minimal circuitry for increased reliability
- Overload Protection
- Rugged mechanical design
- Standard 9V battery
Spec Summary:
Ranges: |
200mVAC, 2000mVAC, 200mVDC, 2000mVDC |
Resolution: |
0.1mV |
Accuracy DCV: |
±(0.5%rdg + 1dgt) |
Accuracy ACV: |
±(1.2%rdg + 3dgts) 50-500Hz |
Measurement rate: |
2.5 times per second, nominal |
Operating environment: |
32ºF to 122ºF at < 70% relative humidity |
Overload Protection: |
30VDC or 24VAC |
Power: |
Single standard 9-volt battery |
Battery Life: |
200 hours |
Note: A Fieldpiece accessory head is needed to operate this unit. |