The UEi Carbon Monoxide Analyzer Kit can ensure an environment safe from combustion gas dangers
The CO91 is used to check ambient CO levels, find leaks along flue pipes, or measure CO concentration in flue gas from furnaces or residential combustion appliances. With a link to the infrared printer, results can be printed to document test results, including the date and time. Perform adjustments to the appliance, and then recall the highest level of CO with the CO Max function. With the temperature function you are able to test register outlet temperatures, or monitor stack gas temperature.
UEi Carbon Monoxide Analyzer Kit Manual
Click the link(s) above to open the document(s) for this item. Should you wish to download it, right click on the link and select "Save Target As..." or "Save Link As...".
If you do not have Acrobat Reader, click here to download the latest version.
Features:
- Kit Includes:
- CO91 – CO Gas Analyzer
- Simple to operate DMM style selector
- Measures ambient CO levels, or CO concentration in flue gas
- Temperature measurement for ambient or stack gas
- Link to infrared printer with date and time
- Auto-zero at power up
- CO Max captures highest value
- KMIRP2 Infrared Thermal Printer
- Compact design with a protective rubber boot
- Integrated magnet
- Infrared port, receives readings up to 3' away without losing connection. Allowed 60˚ angle up to 18” away
- Communicates with UEi analyzers and analyzers using HP protocols
- Self test and battery condition function
- Detects incorrect or missing information
- ATT100 Temperature Probe
- AACA4 AC Adapter
- 2 Rolls of Thermal Paper
- Particle Filter
- Protective Soft Cover Carrying Case
Spec Summary:
| Temperature |
|
Resolution: |
1.0°F |
Accuracy: |
±5.0°F
±0.3% reading |
Range: |
32-1,112°F |
| Gas Measurement |
|
Carbon Monoxide |
|
Resolution: |
1 ppm |
Accuracy: |
±10 ppm<100 ppm*
±5% of reading>100 ppm |
Range: |
1-1,999 ppm |
| Dimensions |
|
Weight: |
2.2lb/1kg |
Handset: |
7.9" x 1.8" x 3.5" |
Probe: |
L11.8 x Dia .25/7.8" long stainless steel shaft |
Ambient
Operating Range: |
32-104°F
10% to 90% RH non-condensing |
Battery Life: |
4 AA cells
>8 hours using Alkaline AA cells |
* Using dry gases at Standard Temperature and Pressure |